Our Products

Calibrated Intrasense

The IntraSense series are absolute pressure sensors designed to fit into a 1-French hypo tube. The sensor comes pre-attached to cabling, simplifying the connection for the end user. The fully encapsulated electronics allow the device to be easily integrated. This sensor compares pressure in vivo to an onboard vacuum cavity for reference to an absolute standard. It delivers accurate and stable pressure for acute procedures in the clinically useful range of -300 mmHg to +500 mmHg (460 mmHg to 1260 mmHg absolute) and from 10°C to 60°C. The output is stable in 37°C liquid, and every part is calibrated and tested in DI water.

These devices are delivered with an attached PCB with a 5-pin right angle header offering fully temperature-compensated output, with both digital and amplified analog noise-filtered outputs.

Technical Data

Key Specifications

  • Miniature sized sensor: 750 μm × 220 μm × 75 μm.
  • Fits within 1-French catheter tubes.
  • Typical drift <2 mmHg over the lifetime
  • PCB with a 5-pin connector on the proximal end
  • Fully temperature-compensated digital and amplified analog outputs.
  • RoHS and REACH Compliant.
  • Biocompatible Materials

Product Configurations

Part Number Pressure Range (mmHg) Compensated Temperature Range (°C) Supply Voltage (V) Design Feature
SMI-1A-48-060-BMAP -300 to +500 10 to 60 3.3 60 cm Cable, standard sensor
SMI-1A-48-100-BMAP 100 cm Cable, standard sensor
SMI-1A-48-180-BMAP 180 cm Cable, standard sensor
SMI-1B-48-060-BMAP 60 cm Cable, light shielded sensor
SMI-1B-48-100-BMAP 100 cm Cable, light shielded sensor
SMI-1B-48-180-BMAP 180 cm Cable, light shielded sensor
SMI-1A-48-060-BMAR 5.0 60 cm Cable, standard sensor
SMI-1A-48-100-BMAR 100 cm Cable, standard sensor
SMI-1A-48-180-BMAR 180 cm Cable, standard sensor
SMI-1B-48-060-BMAR 60 cm Cable, light shielded sensor
SMI-1B-48-100-BMAR 100 cm Cable, light shielded sensor
SMI-1B-48-180-BMAR 180 cm Cable, light shielded sensor

Applications

  • Embolization
  • Thermodilution
  • Intracranial Pressure
  • Compartment Syndrome
  • Atrial Ablation
  • Microvascular Obstruction
  • Fractional Flow Reserve (FFR)
  • Endourology
  • Atherectomy
  • Animal Testing
  • Reproductive Health
  • Glaucoma
  • Resuscitative Balloon Occlusion of the Aorta
  • Endoscopy
  • Aortic Control
  • Cochlear Implant

Downloads

Calibrated Intrasense datasheet (pdf)

Intrasense: Uncalibrated Vs. calibrated series (pdf)

Safety considerations for medically invasive sensors (pdf)

Similar Articles

Product Inquiry

Please contact us. We will get back to you as soon as possible.
Product Inquiry

Product
Calibrated Intrasense

I have taken note of the privacy policy. Note: You can revoke your consent at any time for the future by sending an email to info@mev-elektronik.com.

Your Contact Person

Pascal Wittfeld

Field Application Engineer

+49 (0)5424 2340-54

write email
Contact us!
Please enter one ore more search terms.
crossmenu linkedin facebook pinterest youtube rss twitter instagram facebook-blank rss-blank linkedin-blank pinterest youtube twitter instagram