Data Table
Parameter | Test Condition | Min. | Typ. | Max. | Units |
Gain | 8-12 GHz | 35 | dB | ||
Flatness | 8-12 GHz | +-3 | dB | ||
OP1dB | 8-12 GHz | 34 | dBm | ||
OIP3 | 8-12 GHz | 37 | dBm | ||
VSWR | 8-12 GHz | 2:1 | |||
DC Voltage | 8-12 GHz | 8 | V | ||
DC Current | 8-12 GHz | 3.2 | A | ||
RF Power | 8-12 GHz | 20 | dBm |
SIZE 37.5 × 39.1 × 11.3 mm
Environmental Ratings
TEMPERATURE: -40ºC TO +85ºC (OPERATING)
HUMIDITY: MIL-STD-202G, METHOD 103B COND. B
SHOCK: MIL-STD-202G, METHOD 213B COND. B
VIBRATION: MIL-STD-202G, METHOD 204D COND. B
ALTITUDE: MIL-STD-202G, METHOD 105C COND. B
TEMP. SHOCK: MIL-STD-202G, METHOD 107G COND. A