Data Table
Parameter | Test Condition | Min. | Typ. | Max. | Units |
Insertion Loss | 0.1-18 GHz |
4 |
5 | dB | |
VSWR | 0.1-18 GHz | 1.4:1 | 1.6:1 | ||
Attenuation Step | 0.1-18 GHz | 1 | dB | ||
Attenuation Range | 0.1-18 GHz | 31 | dB | ||
Control Type | 0.1-18 GHz | 5 | bits | ||
Attenuation Flatness |
0.1-18 GHz 0-31 dB |
+-1 | dB | ||
Attenuation Accuracy |
0.1-18 GHz 0-15 dB |
dB | |||
Attenuation Accuracy |
0.1-18 GHz 16-31 dB |
+-0.5 +-0.6 |
+-1 +-1.5 |
dB | |
Temperature Drift |
0.1-18 GHz 0-31 dB |
+-0.5 | dB | ||
Switching Time (ON) | 0.1-18 GHz | 90 | ns | ||
Switching Time (OFF) | 0.1-18 GHz | 90 | ns | ||
Power Handling | 0.1-18 GHz | 25 | dBm | ||
Vdd | 5 | V | |||
Idd | 10 | mA | |||
Vss | -5 | V | |||
Iss | 10 | mA |
SIZE 50.8× 76.2 × 20.8 mm
Environmental Ratings
TEMPERATURE: -40ºC TO +85ºC (OPERATING)
HUMIDITY: MIL-STD-202G, METHOD 103B COND. B
SHOCK: MIL-STD-202G, METHOD 213B COND. B
VIBRATION: MIL-STD-202G, METHOD 204D COND. B
ALTITUDE: MIL-STD-202G, METHOD 105C COND. B
TEMP. SHOCK: MIL-STD-202G, METHOD 107G COND. A