Data Table
| Parameter | Test Condition | Min. | Typ. | Max. | Units | 
| Insertion Loss | 0.1-27 GHz | 
 4  | 
6 | dB | |
| VSWR | 0.1-27 GHz | 1.4:1 | 1.6:1 | ||
| Attenuation Step | 0.1-27 GHz | 1 | dB | ||
| Attenuation Range | 0.1-27 GHz | 31 | dB | ||
| Control Type | 0.1-27 GHz | 5 | bits | ||
| Attenuation Flatness | 
 0.1-27 GHz 0-31 dB  | 
+-1 | dB | ||
| Attenuation Accuracy | 
 0.1-27 GHz 0-15 dB  | 
+-0.5 | +-1 | dB | |
| Attenuation Accuracy | 
 0.1-27 GHz 16-31 dB  | 
+-0.6 | +-1.5 | dB | |
| Temperature Drift | 
 0.1-27 GHz 0-31 dB  | 
+-0.5 | dB | ||
| Switching Time (ON) | 0.1-27 GHz | 90 | ns | ||
| Switching Time (OFF) | 0.1-27 GHz | 90 | ns | ||
| Power Handling | 0.1-27 GHz | 25 | dBm | ||
| Vdd | 5 | V | |||
| Idd | 10 | mA | |||
| Vss | -5 | V | |||
| Iss | 10 | mA | 
SIZE 20 × 30 × 9 mm
Environmental Ratings
TEMPERATURE: -40ºC TO +85ºC (OPERATING)
HUMIDITY: MIL-STD-202G, METHOD 103B COND. B
SHOCK: MIL-STD-202G, METHOD 213B COND. B
VIBRATION: MIL-STD-202G, METHOD 204D COND. B
ALTITUDE: MIL-STD-202G, METHOD 105C COND. B
TEMP. SHOCK: MIL-STD-202G, METHOD 107G COND. A