Data Table
Parameter | Test Condition | Min. | Typ. | Max. | Units |
Insertion Loss |
2-18 GHz 18-32 GHz |
10 15 |
dB | ||
VSWR | 2-32 GHz | 2:1 | 2.5:1 | ||
Attenuation Step | 2-32 GHz | 1 | dB | ||
Attenuation Range | 2-32 GHz | 63 | dB | ||
Control Type | 2-32 GHz | 6 | bits | ||
Attenuation Accuracy |
2-32 GHz 0-31 dB |
+-2 | dB | ||
Attenuation Accuracy |
2-32 GHz 32-63 dB |
+-5 | dB | ||
Switching Time (ON) | 2-32 GHz | 100 | ns | ||
Switching Time (OFF) | 2-32 GHz | 100 | ns | ||
Power Handling | 2-32 GHz | 25 | dBm | ||
Vdd | 5 | V | |||
Idd | 50 | mA | |||
Vss | -5 | V | |||
Iss | 50 | mA |
SIZE 27.6× 64 × 9 mm
Environmental Ratings
TEMPERATURE: -40ºC TO +85ºC (OPERATING)
HUMIDITY: MIL-STD-202G, METHOD 103B COND. B
SHOCK: MIL-STD-202G, METHOD 213B COND. B
VIBRATION: MIL-STD-202G, METHOD 204D COND. B
ALTITUDE: MIL-STD-202G, METHOD 105C COND. B
TEMP. SHOCK: MIL-STD-202G, METHOD 107G COND. A